-- Copyright (C) 2022 by  HUAWEI TECHNOLOGIES. All rights reserved.
-- Description: This mib is used for defining huawei's energy management MIB objects
-- Reference: None
-- Version:   V2.09
-- ============================================================================
HUAWEI-ENERGYMNGT-MIB DEFINITIONS ::= BEGIN

        IMPORTS

            IpAddress, Integer32, Counter64, OBJECT-TYPE, MODULE-IDENTITY,
            NOTIFICATION-TYPE
                FROM SNMPv2-SMI
            OBJECT-GROUP, MODULE-COMPLIANCE, NOTIFICATION-GROUP
                    FROM SNMPv2-CONF 
            InetAddressType, InetAddress            
                FROM INET-ADDRESS-MIB           
            DisplayString, DateAndTime, TruthValue, RowStatus
                FROM SNMPv2-TC
            huaweiUtility
                FROM HUAWEI-MIB ;

hwEnergyMngt MODULE-IDENTITY
       LAST-UPDATED "202202280000Z"
       ORGANIZATION "Huawei Technologies Co.,Ltd."
       CONTACT-INFO
"Huawei Industrial Base
  Bantian, Longgang
   Shenzhen 518129
   People's Republic of China
   Website: http://www.huawei.com
   Email: support@huawei.com
 "
            DESCRIPTION "huawei energy management MIB."
            REVISION    "202202280000Z"
            DESCRIPTION "V2.09 Add hwChassisPowerMngt."
            
            REVISION    "202112030000Z"
            DESCRIPTION "V2.08 Add hwTypicalPower, hwBoardTypicalPower."

            REVISION    "201801150000Z"
            DESCRIPTION "V2.07 Modify the description ."

            REVISION    "201712060000Z"
            DESCRIPTION "V2.056 Modify the description of hwEnergySavingMethodIndex."

            REVISION    "201706210000Z"
            DESCRIPTION "V2.05. Modify the description of hwBoardName and hwBoardType ."

            REVISION    "201511110000Z"
            DESCRIPTION "V2.04. Add enum of hwEnergySavingMode:optimal."
            REVISION    "201505300000Z"
            DESCRIPTION "V2.03. Add enum of hwEnergySavingMode:optimal.
                                This is a draft version." 

            REVISION    "201401230000Z"
            DESCRIPTION "V2.02. Add hwEnergyDevId, hwEnergyDevChangeToSleep.
                                This is a draft version."    
        

            REVISION    "201107010000Z"
            DESCRIPTION "V0.114. Add hwPoEType, hwPSEPower.
                                 Modify FTPC table.
                                 This is a draft version."           

            REVISION    "201103141530Z"
            DESCRIPTION "V0.113, add hwEnergyFtpcIpv4TransMode and hwEnergyFtpcTransMode.
                                This is a draft version."           
            
            REVISION    "201103140000Z"
            DESCRIPTION "V0.112, modify hwEnergyFtpcTransFileIpv4Table and hwEnergyFtpcTransFileTable.
                                This is a draft version."           
            
            REVISION    "201103100000Z"
            DESCRIPTION "V0.111, add hwEnergyFtpcObjects, 
                                including hwEnergyFtpcTransFileIpv4Table and hwEnergyFtpcTransFileTable.
                                This is a draft version."

            REVISION    "201102100000Z"
            DESCRIPTION "V0.11, add hwEnergySavingDescReqMode."

            REVISION    "201008060000Z"
            DESCRIPTION "V0.10, modify hwBoardIndex."

            REVISION    "201008050000Z"
            DESCRIPTION "V0.09, modify hwBoardType."

            REVISION    "201008030000Z"
            DESCRIPTION "V0.08, modify watt to milliwatt.
                         Modify enumeration of hwEnergySavingMode.
                         Add boardType and boardDescription."

        REVISION    "201007120000Z"
            DESCRIPTION "V0.08, modify hwPowerStatPeriod."

            REVISION    "201007070000Z"
            DESCRIPTION "V0.06, modify hwPowerStatPeriod."

            REVISION    "201006290000Z"
            DESCRIPTION "V0.05, modify hwEnergySavingMethodEnable value list.
                         Delete hwEnergySavingParameterTable first index 'hwEnergySavingMethodIndex'"

            REVISION    "201006230000Z"
            DESCRIPTION "V0.05, modify hwEnergySavingCapabilityMngtEntry, modify hwEnergySavingMethodTable"

            REVISION    "201006180000Z"
            DESCRIPTION "V0.04, modify hwEnergySavingCapabilityMngtEntry"

            REVISION    "201006170000Z"
            DESCRIPTION "V0.03, modify description for all MIB table"

            REVISION    "201006080000Z"
            DESCRIPTION "V0.02, add hwEnergySavingMethodEntry, add hwEnergySavingCapabilityMngt"

            REVISION    "201005240000Z"
            DESCRIPTION "V0.01 mib initial"

        ::= { huaweiUtility 157 }


    
--
-- Node definitions
--
    
        -- 1.1
        hwSysPowerMgnt OBJECT IDENTIFIER ::= { hwEnergyMngt 1 }

        
        -- 1.1.1
        hwPowerConsumption OBJECT-TYPE
            SYNTAX Counter64
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "This object indicates the accumulated power consumption of an NE."
            ::= { hwSysPowerMgnt 1 }

        
        -- 1.1.2
        hwPowerStatPeriod OBJECT-TYPE
            SYNTAX INTEGER
                          {
                fifteenMinutes(1),
                thirtyMinutes(2),
                oneHour(3),
                oneDay(4),
                oneWeek(5),
                oneMonth(6)
               }
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "This object indicates the update period of power consumption data."
            DEFVAL {oneHour}
            ::= { hwSysPowerMgnt 2 }

        
        -- 1.1.3
        hwAveragePower OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "This object indicates the average power consumption of an NE within a measurement period."
            ::= { hwSysPowerMgnt 3 }

        
        -- 1.1.4
        hwRatedPower OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "This object indicates the rated power consumption of an NE."
            ::= { hwSysPowerMgnt 4 }

        
        -- 1.1.5
        hwThresholdOfPower OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "This object indicates the NE power consumption threshold."
            ::= { hwSysPowerMgnt 5 }

        
        -- 1.1.6
        hwCurrentPower OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "This object indicates the current power consumption of an NE."
            ::= { hwSysPowerMgnt 6 }


        -- 1.1.7
        hwPoEType OBJECT-TYPE
            SYNTAX INTEGER
            {
                pse(1),
                pd(2),
                noPoe(255)
            }
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "powered type:
                PSE(1): power supplier.
                PD(2): powered deivce.
                noPoe(255): not PSE or PD"
            ::= { hwSysPowerMgnt 7 }


        -- 1.1.8
        hwPSEPower OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The output power(milliwatt) by a PSE. For a non-PSE device, the value is zero."
            ::= { hwSysPowerMgnt 8 }

        
        -- 1.1.9
        hwTypicalPower OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "This object indicates the typical consumption of an NE."
            ::= { hwSysPowerMgnt 9 }


        -- 1.2
        hwBoardPowerMngt OBJECT IDENTIFIER ::= { hwEnergyMngt 2 }

        
        -- 1.2.1
        hwBoardPowerMngtTable OBJECT-TYPE
            SYNTAX SEQUENCE OF HwBoardPowerMngtEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "This table describes board-level power consumption attributes."
            ::= { hwBoardPowerMngt 1 }

        
        -- 1.2.1.1
        hwBoardPowerMngtEntry OBJECT-TYPE
            SYNTAX HwBoardPowerMngtEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "The entry of hwBoardPowerMngtTable."
            INDEX { hwBoardIndex }
            ::= { hwBoardPowerMngtTable 1 }

        
        HwBoardPowerMngtEntry ::=
            SEQUENCE { 
                hwBoardIndex
                    Integer32,
                hwBoardType
                    DisplayString,
                hwBoardName
                    DisplayString,
                hwBoardCurrentPower
                    Integer32,
                hwBoardRatedPower
                    Integer32,
                hwBoardThresholdOfPower
                    Integer32,
                hwBoardTypicalPower
                    Integer32
                    }

        -- 1.2.1.1.1
        hwBoardIndex OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "This object indicates the board index."
            ::= { hwBoardPowerMngtEntry 1 }


        -- 1.2.1.1.2
        hwBoardType OBJECT-TYPE
            SYNTAX DisplayString
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "This object indicates the board type."
            ::= { hwBoardPowerMngtEntry 2 }


        -- 1.2.1.1.3
        hwBoardName OBJECT-TYPE
            SYNTAX DisplayString
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "This object indicates the board name."
            ::= { hwBoardPowerMngtEntry 3 }


        -- 1.2.1.1.4
        hwBoardCurrentPower OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "This object indicates the current power consumption of a board."
            ::= { hwBoardPowerMngtEntry 4 }

        
        -- 1.2.1.1.5
        hwBoardRatedPower OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "This object indicates the rated power consumption of a board."
            ::= { hwBoardPowerMngtEntry 5 }


        -- 1.2.1.1.6
        hwBoardThresholdOfPower OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "This object indicates the board power consumption threshold."
            ::= { hwBoardPowerMngtEntry 6 }


        -- 1.2.1.1.7
        hwBoardTypicalPower OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "This object indicates the typical power consumption of a board."
            ::= { hwBoardPowerMngtEntry 7 }



        
        -- 1.3
        hwEnergySavingMngt OBJECT IDENTIFIER ::= { hwEnergyMngt 3 }

        
        -- 1.3.1
        hwEnergySavingMode OBJECT-TYPE
            SYNTAX INTEGER
                {
                userDefined(1),
                standard(2),
                basic(3),
                deep(4),
                optimal(5)
                }
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "This object indicates the NE-level energy saving mode."
            ::= { hwEnergySavingMngt 1 }

        
        -- 1.3.2
        hwEnergySavingMethodTable OBJECT-TYPE
            SYNTAX SEQUENCE OF HwEnergySavingMethodEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "This table is used to query the energy saving mode."
            ::= { hwEnergySavingMngt 2 }

        
        -- 1.3.2.1
        hwEnergySavingMethodEntry OBJECT-TYPE
            SYNTAX HwEnergySavingMethodEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "Entry of energy-saveing method table."
            INDEX { hwEnergySavingMethodIndex }
            ::= { hwEnergySavingMethodTable 1 }

        
        HwEnergySavingMethodEntry ::=
            SEQUENCE { 
                hwEnergySavingMethodIndex
                    Integer32,
                hwEnergySavingMethodEnable
                    INTEGER
                }

        -- 1.3.2.1.1
        hwEnergySavingMethodIndex OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "This object indicates the index of the energy saving mode."
            ::= { hwEnergySavingMethodEntry 1 }

        -- 1.3.2.1.2
        hwEnergySavingMethodEnable OBJECT-TYPE
            SYNTAX INTEGER
            {
                enable(1),
                disable(2)
            }
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "This object indicates the status of the energy saving mode."
            ::= { hwEnergySavingMethodEntry 2 }


        
        -- 1.3.3
        hwEnergySavingParameterTable OBJECT-TYPE
            SYNTAX SEQUENCE OF HwEnergySavingParameterEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "This table describes the variable of the energy saving mode."
            ::= { hwEnergySavingMngt 3 }

        
        -- 1.3.3.1
        hwEnergySavingParameterEntry OBJECT-TYPE
            SYNTAX HwEnergySavingParameterEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "Entry of energy-saveing parameter table."
            INDEX { hwEnergySavingMethodIndex, hwEnergySavingParameterIndex }
            ::= { hwEnergySavingParameterTable 1 }

        
        HwEnergySavingParameterEntry ::=
            SEQUENCE { 
                hwEnergySavingParameterIndex
                    Integer32,
                hwEnergySavingParameterValue
                    DisplayString (SIZE (0..64))
             }

        -- 1.3.3.1.1
        hwEnergySavingParameterIndex OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "This object indicates the index of the energy saving mode."
            ::= { hwEnergySavingParameterEntry 1 }

        -- 1.3.3.1.2
        hwEnergySavingParameterValue OBJECT-TYPE
            SYNTAX DisplayString
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "This object indicates the variable of the energy saving mode."
            ::= { hwEnergySavingParameterEntry 2 }

            

        -- 1.3.4
        hwEnergySavingCapabilityMngtTable OBJECT-TYPE
            SYNTAX SEQUENCE OF HwEnergySavingCapabilityMngtEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "This table describes the energy-saving capability, including energy-saving methods and parameters.
                The index is hwEnergySavingCapabilityDescIndex.
                "
            ::= { hwEnergySavingMngt 4 }

        
        -- 1.3.4.1
        hwEnergySavingCapabilityMngtEntry OBJECT-TYPE
            SYNTAX HwEnergySavingCapabilityMngtEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "The entry of hwBoardPowerMngtTable."
            INDEX { hwEnergySavingCapabilityDescIndex }
            ::= { hwEnergySavingCapabilityMngtTable 1 }

        
        HwEnergySavingCapabilityMngtEntry ::=
            SEQUENCE { 
                hwEnergySavingCapabilityDescIndex
                    Integer32,
                hwEnergySavingCapabilityDescLanguage
                    DisplayString (SIZE (0..64)),
                hwEnergySavingCapabilityDesc
                    OCTET STRING
                    }
        
        -- 1.3.4.1.1
        hwEnergySavingCapabilityDescIndex OBJECT-TYPE
            SYNTAX Integer32 
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "This object indicates the index of the energy saving capability description."
            ::= { hwEnergySavingCapabilityMngtEntry 1 }

        -- 1.3.4.1.2
        hwEnergySavingCapabilityDescLanguage OBJECT-TYPE
            SYNTAX DisplayString 
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "This object indicates the energy saving capability description language."
            ::= { hwEnergySavingCapabilityMngtEntry 2 }

        -- 1.3.4.1.3
        hwEnergySavingCapabilityDesc OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (0..10240)) 
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "This object indicates the energy saving capability description."
            ::= { hwEnergySavingCapabilityMngtEntry 3 }

        
        -- 1.3.5
        hwEnergySavingDescReqMode OBJECT-TYPE
            SYNTAX INTEGER
                {
                snmp(1),
                ftp(2)
                }
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "This object indicates the method of obtaining the energy saving capability description file."
            ::= { hwEnergySavingMngt 5 }



    -- 1.4
        hwEnergyFtpcObjects OBJECT IDENTIFIER ::= { hwEnergyMngt 4 }

-- == Ftpc Table ==
        hwEnergyFtpcTransFileTable OBJECT-TYPE
            SYNTAX SEQUENCE OF HwEnergyFtpcTransFileEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "This table is used to configure transfer file feature related parameters."
            ::= { hwEnergyFtpcObjects 1 }

        
        hwEnergyFtpcTransFileEntry OBJECT-TYPE
            SYNTAX HwEnergyFtpcTransFileEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "Name identifying Transfer configuration"
            INDEX { hwEnergyFtpcSetName }
            ::= { hwEnergyFtpcTransFileTable 1 }

        
        HwEnergyFtpcTransFileEntry ::=
            SEQUENCE { 
                hwEnergyFtpcSetName
                    OCTET STRING,
                hwEnergyFtpcSrcAddrType
                    InetAddressType,
                hwEnergyFtpcSrcAddr
                    InetAddress,
                hwEnergyFtpcVpnName
                    OCTET STRING,
                hwEnergyFtpcHostAddrType
                    InetAddressType,
                hwEnergyFtpcHostAddr
                    InetAddress,
                hwEnergyFtpcServerPort
                    Integer32,
                hwEnergyFtpcUserName
                    OCTET STRING,
                hwEnergyFtpcPassword
                    OCTET STRING,
                hwEnergyFtpcDirectory
                    OCTET STRING,
                hwEnergyFtpcSrcIfName
                    OCTET STRING,
                hwEnergyFtpcTransCfgRowStatus
                    RowStatus,
                    hwEnergyFtpcAction
                    INTEGER,
                hwEnergyFtpcTransMode
                        INTEGER,
                hwEnergyFtpOperStatus
                        INTEGER
             }

        hwEnergyFtpcSetName OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (1..31))
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "Name identifying FTPC Transfer configuration"
            ::= { hwEnergyFtpcTransFileEntry 1 }

        
        hwEnergyFtpcSrcAddrType OBJECT-TYPE
            SYNTAX InetAddressType
            MAX-ACCESS read-create
            STATUS current
            DESCRIPTION
                "Source IP address Type:
                ipv4(1)
                ipv6(2)"
            ::= { hwEnergyFtpcTransFileEntry 2 }

        
        hwEnergyFtpcSrcAddr OBJECT-TYPE
            SYNTAX InetAddress
            MAX-ACCESS read-create
            STATUS current
            DESCRIPTION
                "Source IP address"
            ::= { hwEnergyFtpcTransFileEntry 3 }

        
        hwEnergyFtpcVpnName OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (0..31))
            MAX-ACCESS read-create
            STATUS current
            DESCRIPTION
                "VPN name used for the corresponding connection"
            ::= { hwEnergyFtpcTransFileEntry 4 }

        
        hwEnergyFtpcHostAddrType OBJECT-TYPE
            SYNTAX InetAddressType
            MAX-ACCESS read-create
            STATUS current
            DESCRIPTION
                "Server address type:
                ipv4(1)
                ipv6(2)"
            ::= { hwEnergyFtpcTransFileEntry 5 }

        
        hwEnergyFtpcHostAddr OBJECT-TYPE
            SYNTAX InetAddress
            MAX-ACCESS read-create
            STATUS current
            DESCRIPTION
                "Server IP address"
            ::= { hwEnergyFtpcTransFileEntry 6 }

        
        hwEnergyFtpcServerPort OBJECT-TYPE
            SYNTAX Integer32 (21 | 1025..55535)
            MAX-ACCESS read-create
            STATUS current
            DESCRIPTION
                "Server port used for connection"
            ::= { hwEnergyFtpcTransFileEntry 7 }

        
        hwEnergyFtpcUserName OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (1..85))
            MAX-ACCESS read-create
            STATUS current
            DESCRIPTION
                "User Name used for user validation"
            ::= { hwEnergyFtpcTransFileEntry 8 }

        
        hwEnergyFtpcPassword OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (1..25))
            MAX-ACCESS read-create
            STATUS current
            DESCRIPTION
                "Password used for user validation. Password Length while setting should not be more than
                16 characters, while querying password will be cipher text"
            ::= { hwEnergyFtpcTransFileEntry 9 }

        
        hwEnergyFtpcDirectory OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (0..256))
            MAX-ACCESS read-create
            STATUS current
            DESCRIPTION
                "Local working directory"
            ::= { hwEnergyFtpcTransFileEntry 10 }

        
        hwEnergyFtpcSrcIfName OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (0..48))
            MAX-ACCESS read-create
            STATUS current
            DESCRIPTION
                "Interface Name"
            ::= { hwEnergyFtpcTransFileEntry 11 }

        
        hwEnergyFtpcTransCfgRowStatus OBJECT-TYPE
            SYNTAX RowStatus
            MAX-ACCESS read-create
            STATUS current
            DESCRIPTION
                "The object specifies the status of this table
                entry. When the status is createAndGo, it
                allows to create  and when value is destroy
                it allows to delete the record in the table"
            ::= { hwEnergyFtpcTransFileEntry 12 }

    
        hwEnergyFtpcAction OBJECT-TYPE
            SYNTAX INTEGER {
                                    get(1),
                                    put(2)
                                   }
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "The type of request.
                              get(1): To request a file from the FTP server.
                              put(2): To send a file to the FTP server."
            ::= { hwEnergyFtpcTransFileEntry 13 }


        hwEnergyFtpcTransMode OBJECT-TYPE
            SYNTAX INTEGER {
                                    ftp(1),
                                    sftp(2),
                                    tftp(3)
                                   }
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "The file transfer protocol. Default: FTP."
            ::= { hwEnergyFtpcTransFileEntry 14 }


        hwEnergyFtpOperStatus OBJECT-TYPE
            SYNTAX INTEGER {
                                    opInProgress(1),
                                    opSuccess(2),
                                    opInvalid(3),
                                    opInvalidProtocol(4),
                                    opInvalidSourceName(5),
                                    opInvalidDestName(6),
                                    opInvalidServerAddress(7),
                                    opDeviceBusy(8),
                                    opDeviceError(9),
                                    opFileOpenError(10),
                                    opFileTransferError(11),
                                    opFileChecksumError(12),
                                    opAuthFail(13),
                                    opUnknownFailure(14),
                                    opAbort(15),
                                    opInvalidSourceAddress(16),
                                    opInvalidSourceInterface(17)
                                   }            
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The OperStatus:
                 opInProgress(1): the operation is in process.
                                 opSuccess(2): the operation has been completed successfully.
                                 opInvalid(3): the command is invalid or command-protocol-device combination is unsupported by the system.
                                 opInvalidProtocol(4): invalid protocol is specified
                                 opInvalidSourceName(5) :invalid source file name is specified.    
                                 opInvalidDestName(6): invalid target name is specified.    
                                 opInvalidServerAddress(7): invalid server address is specified
                                 opDeviceBusy(8): the device is in use and locked by another process
                                 opDeviceError(9): device read, write or erase error
                                 opFileOpenError(10) :invalid file name; file not found in partition
                                 opFileTransferError(11) :file transfer was unsuccessfull
                                 opFileChecksumError(12) :file checksum in Flash is invalid
                                 opAuthFail(13) :authentication failure
                                 opUnknownFailure(14) :failure which is unknown
                                 opAbort(15) : transfer operation has been aborted
                                 opInvalidSourceAddress(16): invalid source IP is specified.
                                 opInvalidSourceInterface(17): invalid source interface is specified.
"
            ::= { hwEnergyFtpcTransFileEntry 15 }

                                  hwEnergyTrapObjects OBJECT IDENTIFIER ::= { hwEnergyMngt 10 }
    
                                  hwEnergyDevId OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS accessible-for-notify
            STATUS current
            DESCRIPTION
                "This object identifies the device ID."
            ::= { hwEnergyTrapObjects 1 }       
    
    
                                  hwEnergyNotification OBJECT IDENTIFIER ::= { hwEnergyMngt 11 }
    
                                  hwEnergyDevChangeToSleep NOTIFICATION-TYPE
            OBJECTS { hwEnergyDevId }
            STATUS current
            DESCRIPTION 
                "This notification indicates device entering in the sleeping status."
            ::= { hwEnergyNotification 1 }     



        
        hwEnergyConformance OBJECT IDENTIFIER ::= { hwEnergyMngt 6 }

        
        hwEnergyCompliances OBJECT IDENTIFIER ::= { hwEnergyConformance 1 }

        
        hwEnergyCompliance MODULE-COMPLIANCE
            STATUS current
            DESCRIPTION 
                "Description."
            MODULE -- this module
                MANDATORY-GROUPS { hwEnergyFtpcGroup }
            ::= { hwEnergyCompliances 1 }

        
        hwEnergyGroups OBJECT IDENTIFIER ::= { hwEnergyConformance 2 }

        
        hwEnergyFtpcGroup OBJECT-GROUP
            OBJECTS { hwEnergyFtpcSrcAddrType, hwEnergyFtpcSrcAddr, hwEnergyFtpcVpnName, hwEnergyFtpcHostAddrType, hwEnergyFtpcHostAddr, 
                hwEnergyFtpcServerPort, hwEnergyFtpcUserName, hwEnergyFtpcPassword, hwEnergyFtpcDirectory, hwEnergyFtpcSrcIfName, 
                hwEnergyFtpcTransCfgRowStatus }
            STATUS current
            DESCRIPTION 
                "Description."
            ::= { hwEnergyGroups 1 }

--      hwSysPowerMgntGroups OBJECT IDENTIFIER ::= { hwEnergyConformance 3 }
        hwSysPowerMgntGroup OBJECT-GROUP
            OBJECTS { hwThresholdOfPower,hwPowerConsumption,hwPowerStatPeriod,hwAveragePower,hwRatedPower,hwCurrentPower,hwPSEPower,hwPoEType,hwTypicalPower }
            STATUS current
            DESCRIPTION 
                "Description."
            ::= { hwEnergyGroups 2 }

--      hwEnergySavingMngtGroups OBJECT IDENTIFIER ::= { hwEnergyConformance 4 }
        
        hwEnergySavingMngtGroup OBJECT-GROUP
            OBJECTS { hwEnergySavingMode,hwEnergySavingMethodIndex,hwEnergySavingParameterIndex,hwEnergySavingCapabilityDescIndex,hwEnergySavingDescReqMode }
            STATUS current
            DESCRIPTION 
                "Description."
            ::= { hwEnergyGroups 3 }

                                    hwEnergyNotificationGroup NOTIFICATION-GROUP
                                                   NOTIFICATIONS { hwEnergyDevChangeToSleep }
                                                   STATUS        current
                                                   DESCRIPTION
                                                   "Description."
                                                   ::= { hwEnergyGroups 4 }

        -- 1.12
        hwChassisPowerMngt OBJECT IDENTIFIER ::= { hwEnergyMngt 12 }

        -- 1.12.1
        hwChassisPowerMngtTable OBJECT-TYPE
            SYNTAX SEQUENCE OF HwChassisPowerMngtEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "This table describes chassis-level power consumption attributes."
            ::= { hwChassisPowerMngt 1 }

        -- 1.12.1.1
        hwChassisPowerMngtEntry OBJECT-TYPE
            SYNTAX HwChassisPowerMngtEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "The entry of hwChassisPowerMngtTable."
            INDEX { hwChassisId }
            ::= { hwChassisPowerMngtTable 1 }

        HwChassisPowerMngtEntry ::=
            SEQUENCE { 
                hwChassisId
                    Integer32,
                hwChassisRealPower
                    Integer32
            }

        -- 1.12.1.1.1
        hwChassisId OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "This object indicates the chassis ID."
            ::= { hwChassisPowerMngtEntry 1 }

        -- 1.12.1.1.2
        hwChassisRealPower OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "This object indicates the real power consumption of a chassis. The value is expressed in mW."
            ::= { hwChassisPowerMngtEntry 2 }

    END

--
-- HUAWEI-ENERGYMNGT-MIB
--